2-6 ADS FlowShark Pulse O&M Manual
depth measurement via water-ultrasonic (and redundant
pressure measurement), and temperature measurement to
compensate for the effect of temperature on the velocity of
sound (combi sensor only)
Types of
Construction
Wedge sensor for installation on pipe bottom
Insertion sensor for installation through pipe wall with nozzle and
cutting ring
Medium
Contacting
Materials
Polyurethane, stainless steel 1.4571, PPO GF30, PA (combi sensor
only)
Option: Sensor made of PEEK, resistant against chemical
substances, Hastelloy mounting plate, Titanium mounting plate, FEP
coated cable
Depth Measurement – Water-Ultrasonic
Measurement
Range
0 to 6.56 feet (0 to 200 cm), lowest absolutely measurable depth
0.13 feet (4 cm)
Zero Point Drift
Absolutely stable
Measurement
Error
Less than ±0.08 inches (±2 mm)
Depth Measurement – Pressure
Measurement
Range
0 to 11.5 feet (0 to 350 cm)
Zero Point Drift
Maximum 0.75% of final value (32 °F to 122 °F (0 – 50 °C))
Measurement
Error
<
0.5% of final value
Depth Measurement – External Sensor
Measurement
Range
Zero Point Drift
Based on device
Measurement
Error
Flow Velocity Measurement
Measurement
Range
-3.28 to 19.7 feet per second (-100 to +600 cm/s)
Number of Scan
Layers
16 (maximum)
Zero point drift
Absolutely stable zero point
Error Limits
(per scan layer)
<
1% of measurement value (v >3.28 feet per second (1 m/s))
<
0.5 % of measurement value 0.2 inches per second (+5 mm/s) (v
<3.28 feet per second (1 m/s))
Number of
Sensors
1 to 3 per transmitter