User Manual
Sensor Installation and Connection  3-5 
  Flow Traveling at Least One Foot Per Second Slower 
flows enable debris to settle in the pipe, limiting the accuracy 
of flow measurements. 
  Higher Elevation than High Water Level that Occurs 
in Wet Well at Downstream Pump Station Pipes that are 
below the high water level of the pump station wet well could 
experience frequent backup and surcharging. This will increase 
sensor maintenance and possibly reduce data accuracy.  
Pipe and Manhole Characteristics  
The physical characteristics of the pipe affect the flow and 
determine the procedure for installing the sensors. Consider the 
following factors and perform the following activities when 
installing the sensors and monitor: 
  Sensor Installation Method Pipe size and shape determine 
the installation method to employ for installing the sensors. 
  Standard Installation Select this option to install 
sensors in round pipes from 8 inches (200 mm) to 48 
inches (1219 mm) in diameter. Standard installations 
involve attaching sensors to an adjustable stainless steel 
ring that mounts inside the pipe.  
  Special Installation Select this option to install sensors 
in non-round pipes or round pipes larger than 48 inches. 
(1219 mm) in diameter. Special installations involve 
attaching sensors to steel bands secured to the inside of the 
pipe. 
  Pipe Height and Width Measure and record the horizontal 
and vertical pipe dimensions carefully. Inaccurate pipe 
measurements—even slightly inaccurate measurements--can 
skew and misrepresent flow data. 