User Manual

2-18 ADS TRITON+ Manual
Based o n this information, the sensor determines the peak velocity
of the oncoming flow. ADS’s analytical and data processing
software calculates an average velocity from this peak by applying a
user-defined average-to-peak ratio.
Ultr a s onic Depth Sensor
The Ultrasonic Depth Sensor with a standard 30-foot (9.1-m) cable
(ADS p/n 8K-CS5-D1-00-30) mounts at the crown of the pipe and
measures ultr asonic depth.
Ultrasonic Depth Sensor
This sensor first transmits an ultrasonic signal downward from one
of the crystals on the sensor face that bounces off the flow surface
and returns to the other crystal. The monitor measures the travel
time elapsed between transmission and reception of the reflected
sound signal. Based on the elapsed time and the speed of sound, the
monito r determines the range. The range r ep r esents the distance
between the sensor face and flow surface. The monitor calculates
the depth o f t he flow by subtracting the range from the pip e
diameter. It compensates for the speed of sound in the air using the
temperatur e recorded by a temperature sensor housed within t he
ultra s onic d epth sens or.