User Manual
A-2 ADS TRITON+ Manual
Power
Internal: One 12-volt, 110 AH, IS alk al i ne battery
pack
External (option): E xternal P ower and
Communications Unit (ExPAC) with an ADS- or
customer-supplied 9- to 36-volt (mi ni mum 15
watt) DC power supply.
Battery Life
15 months at 15-m i nut e sample rat e with one
Peak Combo Sensor and weekly pull
communications (i. e. , data collects)
11 mont hs at 15-minute sample rat e with one
Peak Combo Sensor and hourly push
communications to FTP site
Actual battery li fe will vary depending on
operating temperature, number of active devices
operated, and frequenc y of communicati ons.
Connectors
U.S. MIL-C-26482 series 1, for environmental
sealing, with gold-pl at ed contacts and interfac ial
seals
Inputs and
Outputs
• 2 configurable sens or inputs
• 1 communi c ation connect or f or di rect
interfac e with a computer, external power
input and external communications, or water
quality sampler output cable connec t i on
• 1 antenna port
• 1 SIM card enclosure with an air pres sure
valve (for t esting purposes onl y)
Memory
832 kilobytes
Data Storage
150 days for 6 s tored entities (Peak Combo
Sensor) at a 15-minute sample rate – Refer to
Calculati ng the Total Days of Storage Av ai l abl e
on page A-3 for detai l s and instruc tions on
calcul ating the number of days of data that can
be stored in memory for a specific appl i cation.