User Manual
Maintenance a n d Troubleshooting   10-53 
Problem 
Individual P E AKVEL_1 or PEAKVEL_3 values 
consistently read -9.99. 
Possible 
Causes 
Sensor may be faulty. 
5-volt fuse on regulator may have blown. 
Possible 
Solutions 
Replace the Peak Combo Sensor or Surf ac e Combo 
Sensor. 
Replace t he 5-volt bl ue f use (when replaceabl e) on the 
regulator. 
Caution: Do not connect a questionable sensor to 
another monitor before verifyi ng t he i ntegrity of the 
sensor.  A shorted sensor will blow the 5-volt (blue) 
replacement fuse on the regulator in the monitor. 
Surface Velocity Subsys tem 
The following ta bles contain general troubl eshooting techniques for 
the surface velocity subsystem corresponding to the Surface Combo 
Sensor. 
Problem 
Veloci t y readings are erratic or incorrect. 
Possible 
Causes 
Sensor may be dirty or covered by debris.  
Maximum Velocity setting may require adjustment. 
Transmit Frequ en cy setting may require adjust ment. 
Possible 
Solutions 
Clean the sens or transmi t /receive surfaces. 
Fine-tune Maximum Velocity setting i n device 
parameters. 
Test ot her Transm it Frequency settings i n the velocity 
parameters. 