User Manual
Maintenance a n d Troubleshooting   10-51 
Problem 
Veloci t y dat a does not fluc t uate much (but is not 0). 
Possible 
Causes 
Sensor may be dirty. 
Minimum flows m ay be oc curring within the sens or 
deadband (extending 1.0 inches (25 mm) up from the 
bottom of the Peak Combo Sensor). 
Veloci t y f unction may be broken. 
Possible 
Solutions 
Clean the sensor’s trans mit/ receive surfaces. 
Verify that minimum flows are occurring outside the 
sensor deadband.  
Check the sensor connections. 
Check the vel oc i ty parameters . 
Contact your regional ADS representative. 
Replace the velocity sensor. 