User Manual
10-34 ADS TRITON+ Manual  
Some problems that occur will not require a site visit, such as 
incorrect equipment identification numbers or other system 
parameters the user can re-enter on the local PC. However, some 
prob le ms will require a site visit. Whe n this is necessary, inform 
the data analyst any time a field crew is en route to a monitor site to 
troubleshoot problems so that the analyst can attemp t to collect the 
monito r data before they arrive. If the pro blem is a fa ulty monitor 
and the analyst cannot collect the data remotely, rep lace the moni tor 
and deliver the faulty monitor to the office so the analyst can 
attempt to collect the da ta directly. The n, send the monitor to ADS 
for repair. 
Thi s s ectio n provi des gene ral guid elines fo r troublesho oting and 
correc ting problems with the TRITON+ monitor and sensor 
subsystems. 
Gener al Monitor Problems 
The following ta bles contain general troubl eshooting techniques for 
the TRITON+ flow mo nito r .  
Problem 
Tim e stamp on t he collected data is incorrec t. 
Possible 
Causes 
PC cl oc k may have been set t o i ncorrect time when the 
monitor was activated. 
Monitor time zone differenc e f or the PC clock may not 
have been set correc tly when the monitor was ac t i vat ed. 
Monitor cloc k may be faulty. 
Possible 
Solutions 
Verify the time on t he P C clock and c orrec t if necessary. 
Reactivate the monit or to enable the cloc k. 
Verify the time zone setti ng of the monit or. Correc t and 
reactivat e i f necessary. 
Collect the data from the monitor and replace m oni t or i f 
defective. 










