User Manual
Maintenance a n d Troubleshooting 10-21
3. Use needle-nose pliers to gently remove the black foam
pac king material just inside the opening.
4. Pour out the old desiccant beads from the dryer tube.
5. Refill an equivalent amount of new desiccant beads into the
tube.
6. Carefully replace the foam packing into the dryer tube.
7. Replace and tighten the nut on the dryer tube.
8. Secure the dryer tube to the monitor using cable ties, when
applicable.
9. Use the View or Read All func tion in the Qstart software to
fire the sensor and verify that the sensor is working correctly.
Note: Some d esiccant may be reused following a special
process designed to remove the moisture from the beads.
Please consult the desiccant manufacturer for instructions
on performing this pro ced ure, when applicable.
Replac ing the SIM Card
TRITON+ monitors handle communications through an internal
modem that is supported by a replaceable SIM card that reside s in
an enclosure on the monitor top. The SIM card typically requires
replacement only upon failure, which is rare, or when a change in
wir eless carrier occurs. The monitor must be deactiva ted before
replacing the SIM card!
Replace the SIM card (ADS p/n 507181 or customer-supplied) in
the modem in the following way:
1. Deactivate the monitor through Qstart.
2. Remo ve the monitor from the manhole, and place it in a dry,
clean location (i.e., an adequate distance away from the
manhole).