User Manual

9-12 ADS TRITON+ Manual
A typical message exchange, asking for the first 10
registers, would occur as follows:
000064-Tx:3A 30 35 30 33 30 30 30 30 30 30 30 41 45 45 OD
OA
000065-Rx:3A 30 35 30 33 31 34 30 30 30 30 43 32 43 36 30
30 30 30 43 32 43 36 30 30 30 30 43 32 43 36 38
45 33 39 43 32 39 31 30 30 30 30 43 32 43 36 41
41 OD OA
Description Qstart Entity Standard Units of
Measure
Registers
Peak Vel ocity
from Peak
Combo Sensor
PEAKVEL_1 Feet per Sec ond 40000-40001
Upward
Ultrasonic Depth
from Peak
Combo Sensor
UPDEPTH_1 Inches 40002-40003
Pressure Dept h
from Peak
Combo Sensor
PDEPTH_1 Inches 40004-40005
Water
Temperature
from Peak
Combo Sensor
WATERTEMP_1 Fahrenheit 40006-40007
Surface Velocity
from Surface
Combo Sensor
SURFACEVEL_3 Feet per Sec ond 40016-40017
Smart Depth
from the Surface
Combo or
Ultrasonic Depth
Sensor
SDEPTH_3 Inches 40018-40019
Pressure Dept h
from the Surface
Comb Sensor
PDEPTH_3 Inches 40020-40021