User Manual
6-16 ADS TRITON+ Manual   
Edit the Device Parameters located at the bottom of the dialog, and 
then edit the individual tabs as descr ibed in the following sec tions. 
  Physical Offset Enter the measured physical offset for the 
sensor at the time of installation if it was installed offset from 
the bottom center of the pipe. Refer to Chapter 3, Sensor 
Installation and Connection, for instructions on measuring the 
physical offset.  The default physical offset is 0. 
  Channel  Select the channel number of the port on top of the 
monitor to which the device is physically connected. 
  Pipe Height This field displays the pipe height at the 
monitoring po i nt, based on the installation table.  This 
parameter is not editable fro m this location. 
Note: Under normal conditions, the remaining parameters 
corresponding to the Peak Combo device should not 
require modification. Ho wever, if additional adjustments 
are necessary, the following sections provide a detailed 
description of each parameter.  
  Ultrasonic tab - Peak Combo 
Edit the following parameters correspo nd ing to the upward-looking 
ultrasonic depth sensor in the Peak Combo Sensor: 
  Enable Select this checkbox to ensure the monitor begins 
taking upward ultrasonic depth readings at the designated 
interval upon activation. This option is selected by default. 
  Flow Type Select the option that best reflects the kind of 
flow conditions that typically occur at the monitoring point 
from the drop-down list:  
  Typical Flow exhibits a typical diurnal pattern. This is 
the defa ult setting. 
  Wet/Stagnant Flow r e mains in the pipe, but moves only 
duri ng wet weather event s . 
  Usually Dry Pipe typically remains dry, excep t under 
wet weather conditions.  