Operation Manual
GB
Troubleshooting
21
160 Adria Caravans
21.11 Control panel faults
Tab. 24 Control panel faults
Fault Possible cause Remedy
12 V supply does not
function
12 V main switch switched off • Switch 12 V main switch on
(Chapter 10.2).
Fuse defective. • Contact Customer Service.
12 V control indicator
(green) is not lit
12 V supply switched off • Switch on the 12 V supply.
System cannot be
switched on
Living area battery is not
charged or insufficiently
charged.
• Charge the living area battery
Fuse defective • Contact Customer Service.
No voltage is supplied
by the living area bat-
tery
The living area battery is dis-
charged
• Charge living area battery
immediately!
• Deep discharging damages
the living area battery!
Discharge is performed by
inactive appliances, e.g. the
frost protection valve of the
combined heater.
• Charge living area battery for
longer stationary periods.
The "mains control"
symbol is not shown
although the 230 V
mains supply is con-
nected
The mains connection has no
voltage.
• Check the mains connection
(e.g. camping site).
Circuit breaker for 12 V power
supply unit has triggered or is
switched off.
• Reset or switch on the circuit
breaker.