Troubleshooting 21
Adria Caravans 157
21.7 Alde Compact 3010 heater faults
Tab. 20 Alde Compact 3010 heater fault
21.8 Gas stove faults
Tab. 21 Gas stove faults
Important!
Consult an authorised workshop if the listed measures are not successful.
Fault Possible cause Remedy
Heater does not start. See Chapter 21.6 "No gas".
No supply voltage (12 V). Check battery voltage (12 V).
Check all electric connectors
and fuses.
Electrical operation
(230 V) not possible.
No mains voltage. Check the circuit breaker is
switched on.
Check the 230 V plug is con-
nected to the heater system.
Check 230 V voltage is availa-
ble at the socket.
Fault Possible cause Remedy
No gas See Chapter 21.12 "No gas".
Flame extinguishes in
the "small flame"
position
Flame failure device is not
adjusted correctly.
Adjustment exclusively by
authorised workshop.
Flame failure device
does not react
Flame failure device is defec-
tive.
Consult an authorised work-
shop.
Flame appearance on
appliance not normal
Gas pressure regulator defec-
tive.
Consult an authorised work-
shop.