Operation Manual

DD
Heater & hot water 13
Adria Motorhomes 97
13.1.1 Placing into service
Check the following each time before placing the heater into service:
Is the exhaust cowl free?
Otherwise remove the cover from the exhaust cowl.
Is the shut-off valve of the gas cylinder open?
Is the "Heater" quick-action stop valve on the distributor block open?
For electrical operation (Truma Combi E):
Is the circuit protection for the 230V power supply at the camping site adequate?
(900W - 3.9A / 1800W - 7.8A)
Has the connecting cable been fully unwound from the cable reel?
Is the 230 V circuit breaker in the vehicle switched on?
Fig. 70 Truma Combi and Truma Combi E control
switch
1 Rotary knob for room temperature
2 Green "Operation" indicator lamp
3 Summer mode
(hot water preparation 40 °C or
60 °C without heating)
4 Winter mode
(Heating without hot water prepa-
ration or with empty water system)
5 Winter mode
(Heating with hot water prepara-
tion 60 °C)
6 Rotary "Off" switch
7 Yellow "Boiler heating" indicator
lamp
8 Red "Failure" indicator lamp
Important!
Heating is always possible in all operating modes (gas, electric and mixed operation) with
and without water.
Combi
2
1
3
4
5
1
6
4
5
3
60°
40°
60°
7
8
2