Operation Manual
DD
Gas system
11
84 Adria Motorhomes
11.6.1 Placing the SecuMotion/MonoControl CS into service
Placing the SecuMotion/MonoControl CS into service:.
Open the shut-off valve (Fig. 58/1) of the full gas cylinder.
Press the reset knob (green button) (Fig. 58/2) on the high-pressure hose (Fig. 58/3)
firmly and hold it depressed briefly.
Hold the gas flow monitor reset knob (green button) (Fig. 58/4) on the gas pressure reg-
ulator (Fig. 58/5) depressed for approx. 5 seconds.
If required, repeat the process.
The gas appliances can now be placed into service.
11.6.2 SecuMotion/MonoControl CS - changing gas cylinders
Use the screwing tool provided for screwing the high-pressure hose on and off.
The screwing tool ensures the required tightening torque and prevents damage to the screw
connection caused by wrong tools.
Important!
If not used for a longer period and with the gas cylinders closed, the SecuMotion/MonoCon-
trol CS can be switched off.
Fig. 58 Truma-SecuMotion/MonoControl CS
1 Shut-off valve of operating cylin-
der
2 Reset knob (green)
3 High-pressure hose
4 Gas flow monitor reset knob
(green)
5 Gas pressure regulator
1 2 3 54