Power supply 10
Adria Motorhomes 71
Battery disconnect switch (EBL 208 S):
The battery disconnect switch (Fig. 51/4) disconnects the following connections from the living
area battery:
• All 12-V appliances except the AES refrigerator and the entrance step
• The control panel
This prevents the slow discharge of the living area battery by quiescent current while the vehi-
cle is placed out of service.
The batteries can still be charged by the transformer/rectifier, the generator or the solar charge
regulator (special accessory) (Fig. 51/6) when the battery disconnect switch (Fig. 51/4) is
switched off.
PolySwitch circuit breaker (EBL 226):
• The entrance step is protected with a self-resetting PolySwitch circuit breaker (Fig. 50/2).
• If a malfunction occurs, the PolySwitch circuit breaker interrupts the electric circuit. After the
malfunction has been cleared, the fuse resets itself after approx. 1 minute.
Battery selector switch:
• Setting the battery selector switch (Fig. 50/10) or (Fig. 51/3) to the wrong position can dam-
age the living area battery.
Disconnect the transformer/rectifier from the mains before setting the battery selector
switch (Fig. 50/10) or (Fig. 51/3) to a different position.
The option of switching over with the battery selector switch ensures optimum charging of the
two battery types (lead-gel or lead-acid).
• Selection of lead-gel battery: Set the battery selector switch to "Lead-Gel".
• Selection of lead-acid battery: Set the battery selector switch to "Lead-Acid".
Use a thin object for the changeover (e.g. ball-point pen refill).