Operation Manual
DD
Power supply 10
Adria Motorhomes 69
10.3 Power supply - external generator (special accessory)
For more information, see the separate instructions from the manufacturer.
10.4 12 V power supply
10.4.1 Transformer/rectifier (power supply unit 230 V/12 V)
The transformer/rectifier is the central power distribution unit of your vehicle. The transformer/
rectifier serves for charging the living area battery and for the power supply of the 12 V appli-
ances. When the living area battery is fully loaded, the transformer/rectifier automatically
charges the starter battery of the basic vehicle.
Caution!
Damage to vehicle electronics
Voltage variations or voltage peaks must not occur.
Make the connection from the generator to the vehicle only when the generator is in
operation.and the output voltage is constant.
Switch the generator off only after the connection between the vehicle and the genera-
tor has been disconnected.
Warning!
Risk of burns
Do not touch the rear of the transformer/rectifier during operation. The rear of the trans-
former/rectifier becomes hot during operation.
Caution!
Damage to power supply unit
Replace defective fuses only when the cause of the defect is known and has been rem-
edied.
Never bridge or repair fuses.
Use only original fuses with the values specified in the separate instructions from the
manufacturer.
Replace defective fuses only when the transformer/rectifier has been de-energised.
Do not lay any cables underneath the power supply unit due to the heat generation.