Operation Manual

DD
Troubleshooting 21
Adria Motorhomes 167
21.10 Control panel faults
Tab. 21-14 Control panel faults
21.11 Toilet faults
Tab. 21-15 Toilet faults
Fault Possible cause Remedy
12 V supply does not
function
12 V main switch switched off Switch 12 V main switch for
living area battery on
(Chapter 8.8).
Fuse defective Contact Customer Service.
12 V control indicator
(green) is not lit
12 V supply switched off Switch on the 12 V supply.
System cannot be
switched on
Living area battery is not
charged or insufficiently
charged.
Charge the living area battery
Fuse defective Contact Customer Service.
No voltage is supplied
by the living area bat-
tery
The living area battery is dis-
charged
Charge living area battery
immediately!
Complete discharging dam-
ages the living area battery!
Discharge is performed by
inactive appliances, e.g. the
frost protection valve of the
combined heater.
Charge living area battery for
longer stationary periods.
The "mains control"
symbol is not shown
although the 230 V
mains supply is con-
nected
The mains connection has no
voltage.
Check the mains connection
(e.g. camping site).
Circuit breaker before the
transformer/rectifier has trig-
gered or is switched off.
Reset or switch on the circuit
breaker.
Fault Possible cause Remedy
Toilet does not have
flushing water
Water tank is empty. Fill the water tank.
The pump runs, the
toilet bowl is not emp-
tied
Clogging in toilet bowl. Fill the toilet bowl with water.
Allow clogging to soak for
approx. 2 minutes and then
flush several times in quick
succession.
Toilet does not func-
tion