Operation Manual

DD
Troubleshooting 21
Adria Motorhomes 163
21.6 Truma Combi and Truma Combi E heater faults
Tab. 21-10 Truma Combi and Truma Combi E heater faults
Important!
Consult an authorised workshop if the listed measures are not successful.
Fault Possible cause Remedy
LEDs do not light. No supply voltage. Check battery voltage (12 V).
Check all electric connectors
and fuses.
Green LED lights but
heater does not oper-
ate.
The temperature setting on
the control panel is lower than
the room temperature.
Set the temperature on the
control panel higher.
Green LED lights and
red LED blinks.
Battery voltage is too low. Charge the battery.
The red LED goes on
approx. 30 seconds
after the heater is
switched on.
See Chapter 21.3 "No gas".
After operating for a
longer period of time,
the heater switches to
failure.
Warm air outlet openings
blocked.
Check and free individual sin-
gle warm air outlet openings.
Gas pressure regulator fro-
zen.
Use a regulator de-icing sys-
tem (e.g. Eis-Ex as acces-
sory).
Green and red LEDs
blink after heater is
switched off.
Appliance was switched off
during failure. After-running is
active in order to reduce the
temperature.
After-running will switch off
after a few minutes. The sys-
tem can only be reset after
this time elapses by switching
the system off and on again.
The drain valve
(FrostControl) does
not close.
Temperature on drain valve is
below +3 °C.
Switch the heater on. If the
heater is not in operation, the
drain valve can only be closed
when the ambient tempera-
ture is above +3 °C.
Drain valve rotary switch not
set to "Operation".
Turn the drain valve rotary
switch (Fig. 72/2) to "Opera-
tion". Now press the snap but-
ton (Fig. 72/5) on the drain
valve until it engages.