Operation Manual
DD
Troubleshooting
21
160 Adria Motorhomes
21.3 Gas system faults
Tab. 21-7 Gas system faults
Fault Possible cause Measure
Gas smell,
high gas consump-
tion
Gas system leaks. • Immediately put the gas sys-
tem out of service.
• Close the gas cylinder shut-off
valves.
• Avoid any type of ignition
spark and open light.
• Ventilate the vehicle well
(Chapter 2.5).
• Repair by authorised work-
shop.
No gas Gas cylinder is empty. • Exchange gas cylinder
(Chapter 11.5 and 11.6).
Gas cylinder shut-off valve
closed
• Open gas cylinder shut-off
valve (Chapter 11.6.1).
The SecuMotion/MonoCon-
trol CS gas pressure regulator
(special equipment) has
switched off after the gas sys-
tem has not been used for a
longer period of time and with
the gas cylinders shut off.
• Place the SecuMotion/Mono-
Control CS (special equip-
ment) into service
(Chapter 11.6.1).
Gas pressure regulator fro-
zen.
• Use a regulator de-icing sys-
tem (e.g. Eis-Ex as acces-
sory).
Quick-action stop valve
closed
• Open quick-action stop valve
(Chapter 11.7).
Appliance is defective. • Repair by authorised work-
shop.
Outside temperature too low. • Use propane gas for winter
camping (Chapter 11.3).
Flame appearance on
appliance not normal
Gas pressure regulator defec-
tive.
• Consult an authorised work-
shop.