14.1.1 Operation
Switching the gas stove on:
Clean the gas stove before placing it into service (Chapter 19.2.5).
Lift the glass cover (Fig. 79/3, special equipment) of the cooking area (Fig. 79/2) up and,
when necessary, fit the aluminium protective covers (special equipment).
Open the gas cylinder shut-off valve (Fig. 59/1) and the quick-action stop valve
(Fig. 61/3) on the distributor block.
Turn the control knob (Fig. 79/1) of the desired cooking position (Fig. 79/2) to "large
flame", press it and keep it depressed.
Gas flows out.
Ignite the gas flowing out with a suitable device and keep the control knob (Fig. 79/1)
depressed for approx. 10 seconds until the flame safety device keeps the gas supply
open.
If the flame goes out, repeat the process.
Regulate the gas supply by turning the control knob to the "large flame" or "small flame"
symbol.
Caution!
Defective cooking area
The burner does not operate properly. The flame goes out again and again despite the
control knob being depressed for an extended period of time.
The thermal element is bent or defective. Have defective thermal elements replaced by
an authorised workshop. We recommend yearly inspection by a specialist.
Important!
Always make sure the respective control knob is set to "Off" when you are finished using
the cooking stove, the grill or the oven.
On models with electric ignition, proceed in the same manner as described, however, the
flame is ignited by pressing the button for electric ignition on the control panel.
Fig. 79 Gas stove
1 Control knob
2 Cooking area
3 Glass cover (special equipment)
1
2
3