Operation Manual
DD
Heater & hot water
13
104 Adria Motorhomes
13.2.1 Placing into service
Check the following each time before placing the heater into service:
In gas operation:
Is the exhaust cowl free?
Otherwise remove the cover from the exhaust cowl.
Is the shut-off valve of the gas cylinder open?
Is the "Heater" quick-action stop valve on the distributor block open?
In electrical operation:
Is the circuit protection for the 230V power supply at the camping site adequate? (1 kW
~ 4.4 A/2 kW ~ 8.7 A/3 kW ~ 13.1 A)?
Has the connecting cable been fully unwound from the cable reel?
Fig. 73 Overview of control panel symbols
1 Clock
For setting the clock, see the sep-
arate instructions from the manu-
facturer.
2 Outside temperature
The outside temperature is indi-
cated when the sensor has been
installed.
3 Inside temperature
The inside temperature is indi-
cated.
4 Circulation pump
The symbol is displayed when the
pump is in operation.
5 Automatic cylinder switch-over
The symbol is displayed when an
automatic cylinder switch-over
(special accessory) is connected
and activated.
6 Mains voltage 230 Volt
The symbol is displayed when a
voltage of 230 Volt is applied to
the heater.
7 Button "MENU"
Button for the settings menu.
8 Button "On/Off"
Main switch of the heater.
Important!
• Heating is always possible in all operating modes (gas, electric and mixed operation)
with and without water.
• Heating with electricity is to be preferred to heating with gas.
10100067
1
2
3
4 5 6
78