Operation Manual

DD
Heater & hot water
13
104 Adria Motorhomes
13.2.1 Placing into service
Check the following each time before placing the heater into service:
In gas operation:
Is the exhaust cowl free?
Otherwise remove the cover from the exhaust cowl.
Is the shut-off valve of the gas cylinder open?
Is the "Heater" quick-action stop valve on the distributor block open?
In electrical operation:
Is the circuit protection for the 230V power supply at the camping site adequate? (1 kW
~ 4.4 A/2 kW ~ 8.7 A/3 kW ~ 13.1 A)?
Has the connecting cable been fully unwound from the cable reel?
Fig. 73 Overview of control panel symbols
1 Clock
For setting the clock, see the sep-
arate instructions from the manu-
facturer.
2 Outside temperature
The outside temperature is indi-
cated when the sensor has been
installed.
3 Inside temperature
The inside temperature is indi-
cated.
4 Circulation pump
The symbol is displayed when the
pump is in operation.
5 Automatic cylinder switch-over
The symbol is displayed when an
automatic cylinder switch-over
(special accessory) is connected
and activated.
6 Mains voltage 230 Volt
The symbol is displayed when a
voltage of 230 Volt is applied to
the heater.
7 Button "MENU"
Button for the settings menu.
8 Button "On/Off"
Main switch of the heater.
Important!
Heating is always possible in all operating modes (gas, electric and mixed operation)
with and without water.
Heating with electricity is to be preferred to heating with gas.
10100067
1
2
3
4 5 6
78