User Manual

Advanced RF Technologies, Inc.
47
8. SPECIFICATIONS
8.1 Electrical Specifications
Table 8-1 Electrical Specifications (PSR Series)
Parameters
Specifications
Remark
DL
UL
Frequency Range
(MHz)
FirstNet + PS 700
758 - 768
788 - 798
Support
PS 800
N/A
Composite Output
Power (PSR-78-9537-
XB)
FirstNet / PS 700 /
FirstNet + PS 700
37 dBm
30 dBm
Support
PS 800
37 dBm
30 dBm
N/A
FirstNet + PS 700 +
PS 800
40 dBm
(37dBm + 37dBm)
30 dBm
N/A
System Gain (dB)
95
95
Filter selection
Broad / Narrow / Broad + Narrow band
Only Broad band
Simultaneous Filter
Support numbers
Broad Band
2 (non-contiguous) @ FirstNet / PS 700 / PS 800 /
FirstNet + PS 700 / FirstNet + PS 700 + PS 800
2 (non-contiguous) @ FirstNet
Narrow Band
Up to 32 (Non-contiguous) @ PS 700 / PS 800
Up to 32 (Non-contiguous) @ PS 700 + PS 800
Filter Bandwidth
Broad (MHz)
3, 5, 10
LTE 5 & 10 MHz
Narrow (KHz)
6.25, 12.5, 25, 75, 200
N/A
Filter Roll-off
Broad (MHz)
60dBc@Filter Bandwidth Edge + 1MHz
Narrow (KHz)
55dBc @Filter Bandwidth Edge + 3 * Filter BW
Spurious
3GPP Rule Compliant
Passband Ripple
±2 dB
ALC Dynamic Range
≥ 60dB
Gain Dynamic Range
45dB
Channel Setting Resolution
0.025 KHz
Noise Figure @ Max. gain
≤5dB
System
Group Delay
Broad Band
<6us
Narrow Band
<126us@6.25KHz BW, <67us@12.5KHz BW,
<36us@25KHz BW, <18us@75KHz BW,
<10us@200KHz BW
Power Supply
100 -240 VAC, 60 Hz (Free Voltage)
Optional battery backup
Power Consumption (PSR-78-9537-XB / 9537)
150 W / < 222 W
Max RF Input Power without overdrive
-20dBm
No damage Max Input Power
+10 dBm
Impedance
50 Ω
VSWR
1.5 : 1
Dry Contacts
NFPA 1221 2016 Code Compliant
Remote Alarming /
Network Management
Dry Contacts, Web-GUI, SNMP, (External Wireless
Modem Required)
Humidity
5% - 95% RH Condensed
Operating at Ambient Temperature
-40°F to +140°F (-40°C to +60°C)