5.3.3 Manual Gain Control
Figure 5-13 Control Tab Manual Gain Control
DL/UL Gain: Gain levels of the repeater can be specified here
DL/UL ALC Level: Prevents the output power from exceeding the specified value
DL/UL Output ALC Offset: If any ALC attenuation has been applied, the system will release this
attenuation when the signal level drops by the specified level
DL /UL Gain Balance ON: Allows the user to enable or disable the gain balance. When gain balance is
enabled, the delta value between the downlink and uplink gains remain constant
5.3.4 Alarm Settings & Battery Alarm Settings
Figure 5-14 Control Tab Alarm & Battery Alarm Settings
DL Signal Low Level: Allows the user to specify how low the signal can be before triggering a Downlink
Signal Low” soft-fail alarm
DL Signal Not Detected Level: Allows the user to specify how low the signal can be before triggering a
“Downlink Signal Not Detected” soft-fail alarm
DL RF Power Level: Allows the user to set a maximum deviation value for the downlink RF power before
triggering a “DL RF Power Level” soft-fail alarm
- For example, if the input signal is -50 dBm and the gain is set to 60 dB, the expected output power
should be 10 dBm. If the Downlink RF Power alarm value is set to 6dB, then a soft-fail alarm will trigger
if the output power falls below 4 dBm
DL Over Power Level: DL Over Power Alarm will trigger when the DL output level exceeds this level
UL Over Power Level: UL Over Power Alarm will trigger when the UL output level exceeds this level
Battery Check:
Check All All battery related alarms are checked which include Battery Fail, Battery Not Installed, Low
Battery, and Battery Not Charge
Except Install Only Battery Fail, Low Battery, and Battery Not Charge alarms are checked
Check Off Does not perform any battery check
Battery Not Charge Check:
On Checks for the Battery Not Charge alarm
Off Disables the check for the Battery Not Charge alarm