5. PSR-78-9537-XB WEB-GUI SETUP
The Web-GUI allows the user to communicate with the repeater either locally or remotely. To connect to the
repeater locally, you will need a laptop with an Ethernet port and an RJ-45 crossover cable. To connect to the
repeater remotely, you will need to have an active internet connection via an external modem or LAN.
5.1 Repeater/PC Connection Using Web-GUI
Verify that your Local Area Network Connection is set to obtain an IP address automatically under the
Internet Protocol (TCP/IP) properties.
- If you are connecting to the unit remotely (use of a modem), then skip the step above.
Connect the RJ-45 crossover cable between the laptop’s Ethernet port and the repeater’s Ethernet port.
Launch either Internet Explorer or Google Chrome.
Type the following IP address into the address bar of the Internet Browser: http://192.168.63.1
- If you are connecting to the unit remotely, then type the IP address of the modem to connect to the unit
The following login screen will appear:
Figure 5-1 Login Page
If you are not the Administrator, please type in your assigned username & password which you should have
received from the Administrator.
The default username and password for the General User is adrf & adrf, respectively.
The default Administrator login is admin & admin, respectively.