User Manual
Advanced RF Technologies, Inc.
25
External Alarm Name
Set Condition
Donor Antenna Malfunction
- UL Return Power Hard Fail or No DL Signal Detected
Active RF Emitting Device Malfunction
- RF Power Soft Fail
- DL Return Power Hard Fail
- DL/UL Over Power Hard Fail
- DL/UL Input Overload Hard Fail
System Component Malfunction
- Over Current Hard Fail
- Over Temperature Hard Fail
- DSP Hard Fail
- Out-band Overload Hard Fail
3.3.2 External Alarm Input interface
User Alarm Input Port
No
External Alarm In
User Alarm
Remark
1
ALARM IN 1
TBD
4. INSTALLATION
4.1 Installation Procedures
4.1.1 Wall Mount Procedure
Verify that the PSR-78-9537-XB and mounting holes are in good condition
Place the PSR-78-9537-XB mounting bracket template up against the wall and mark off mounting holes
Drill the appropriate size holes and install the included wall anchors
Remove the wall mount bracket from the repeater and bolt the wall mount bracket to the wall
Place the repeater onto the wall mount bracket and secure the bracket to the repeater
Connect the GND cable
Connect the Antenna cables
Connect the Power cable
Figure 4-1 Wall Mount
Wall Mount
Bracket