User Manual

Advanced RF Technologies, Inc. 13
1.4 Warnings and Hazards
Opening the PSR-78-9533-XB could result in electric shock and may cause
severe injury.
Operating the PSR-78-9533-XB with antennas in very close proximity facing
each other could lead to severe damage to the repeater.
WARNING! DAMAGE TO REPEATER
Actual separation distance is determined upon gain of antenna used.
Please maintain a minimum safe distance of at least 400cm while operating near the donor and
the server antennas. Also, the donor antenna needs to be mounted outdoors on a permanent
structure.
RF EXPOSURE & ANTENNA PLACEMENT Guidelines
Opening or tampering the PSR-78-9537-XB will void all warranties.
WARRANTY
Lithium Battery: CAUTION. RISK OF EXPLOSION IF BATTERY IS REPLACED BY INCORRECT TYPE. DISPOSE OF
USED BATTERIES ACCORDING TO INSTRUCTIONS.
WARNING! ELECTRIC SHOCK
In accordance with the FCC regulations, this device must meet 5W ERP requirements.
To satisfy this, the antenna cable name we propose is LMR200. If available, the antenna length must be
at least of 30m (antenna cable loss at 30m is about 8 dBi). If you use another antenna cable, the cable
loss must be considered to more than DL: 2dBi and UL: 7 dBi. So, the maximum antenna gain after
accounting for any cable losses should be UP To DL: 0.6 dBi, Omni antenna / UL: 8 dBi, Pannel antenna.