- ALC: Displays the amount of gain that is attenuated by ALC function.
- ILC: Displays the amount of gain that is attenuated by ILC function.
- Actual: Displays the actual amount of gain that is currently in use.
• Output [dB] – Displays the Downlink/Uplink output power levels. The system will display “--.-“ when the
output level is < +5 dBm.
• Isolation [dB] – Displays the measured isolation value. The value inside of the parenthesis is the “actual gain -
measured isolation value”. When the “actual gain – measured isolation value” is less than -15dB, then “MAX”
will be displayed.
5.2.3 Alarm
This section displays the alarm status for System alarms, RF Alarms, and Power alarms. If an alarm is present
in the system, then the color of the alarm tab will change according to the type of failure.
Figure 5-5 Alarm Display
5.2.4 Message Board
Displays the 40 most recent events.
Figure 5-6 Message Board
• Log File: Downloads the system Log File (events and alarms) to your computer
5.2.5 Install and Power Status
Figure 5-7 Install and Power Status
• Installation: Displays whether or not the installation routine has been run (Not Installed or Installed)
• Power: Displays the power source that is currently being used