User's Manual
Table Of Contents
- 1. Introduction
- 2. Overview
- 3. Alarms
- 4. Installation
- 5. AXM700F-9543-ICS-X Web-GUI Setup
- 6. Maintenance Guide for AXM700F-9543-ICS-X Repeater
- 7. Warranty and Repair Policy
- 8. Specifications
- 9. mechanical drawing
- 10. Appendix
Advanced RF Technologies, Inc.
27
5.2 Status Tab
Figure 5-2 Status Tab
5.2.1 Power & Gain
This section displays the Input, Gain, and Output for both downlink and uplink.
Figure 5-3 Power & Gain Display
• Input [dBm] – Displays the in-band Downlink/Uplink signal level. The system will display “--.-“when the input
level is < -90 dBm.
• Gain [dB]
- User Set: Displays the amount of gain that user set.
- ALC: Displays the amount of gain that is attenuated by ALC function.
- ILC: Displays the amount of gain that is attenuated by ILC function.
- Actual: Displays the actual amount of gain that is currently in use.
• Output [dB] – Displays the Downlink/Uplink output power levels. The system will display --.-“, when the
output level is < +5 dBm.
• Isolation [dB] – Displays the measured isolation value. The value inside of the parenthesis is the “actual gain -
measured isolation value”. When the “actual gain – measured isolation value” is less than -15dB, then “MAX”
will be displayed.
5.2.2 Alarm