User's Manual

Advanced RF Technologies, Inc. 20
3. ALARMS
3.1 Message Board Alarms and Notification
Table 3-1 Message Board Alarms and Notification
Parame
te
r
Remark
AC Fail Power supply is not operating within specs
DC Fail Power supply is not operating within specs
Fan[1/2] Fail System has detected an issue with the fan1 and fan2
Temperature Module is above the normal operating temperature
Current Power supply is not operating within specs
System Halt System is in a shutdown state due to a hard fail alarm
DSP Fault System has detected an issue with the internal DSP chip
OSC Oscillation detected
DL Signal not detected DL signal is below the specified level
DL Signal Low DL signal is below the specified level
Input Overload Incoming in-band DL or UL signal is too strong
Out of band Overload Incoming out-band DL or UL signal is too strong
Synthesizer Lock Fail Issue with internal PLL
DL RF Power Input + gain does not match the output level (above delta of 6 dB)
Overpower Output level is above the max output levels
VSWR Power is being reflected back to the repeater
Heartbeat Heartbeat
Reboot Reboot
Factory setting Factory setting
Door Door alarm set/clear.