6.2.2 RU Installation Procedure
The ADXV RU chassis mounts in a standard 19” (483mm) equipment rack. Allow clearance of 3” (76mm) at the
front and rear, and 2” (51mm) on both sides for air circulation. No top or bottom clearance is required.
Consideration:
- Eight mounting holes are located on 4 corners of ADXV RU to attach it to the 19” rack. The ADXV
RU must be securely attached to a rack that can support the weight of the ADX.
Procedure
- The following steps should be followed while mounting the ADXV RU
Verify that the RU and Mounting holes are in good condition
Set the ADXV DAS RU against the 19”rack and secure the unit with screws
Verify that ADXV RU is securely attached
Connect the GND cable
Connect the RF coaxial cable
Connect the Power
Connect the Optic cable