User's Manual

Advanced RF Technologies, Inc.
33
3.2.1.2 RF port
DL IN/UL OUT connect to ORUs DL port and UL port, it is necessary to connect ULs port number equal to DLs
because of serial communication with ORU.
CPL (-30dB): DL output 30dB coupling
SERVER: DL output, UL input, Server Duplexer port
3.2.1.3 Power port
DC IN: Port for power supply (+27VDC) and communication with Controller inside PSU.
3.2.1.4 LED
LED color
Status
Green
Normal
Yellow
Soft fail
Red
Hard fail
3.2.2 Optical Remote Unit (ORU, ADXV-R-ORU)
Figure 3-20 ADXV-R-ORU Front and Rear View
Spec
- Size: 2.3 x 13.8 x 6.85 (in)
- Weight: 9.26lbs
3.2.2.1 Front port
- DL1-DL6: DL port connect to DL IN of RM (Remote Module) (see 3.2.1.1)
- UL1-UL6: UL port connect to UL OUT of RM (Remote Module) (see 3.2.1.1)
- E-DL/E-UL ports connect to external splitter for extension of band RM
OPTIC
ADXV-R-ORU
DL 1
DL OUT UL IN
DL 2DL 3DL 4DL 5DL 6
UL 1UL 2UL 3UL 4UL 5UL 6
E-ULE-DLSERVICELINKVHF-ULVHF-DL
DC INPSU ALARMGUIFAN