6.2.3 RF coaxial cable and antenna connection
The coaxial cables which are connected to antenna port of RU. Before connection, check the VSWR
value of coaxial cable whether it is within specification using Sitemaster..
At this time, check if the Return loss have above 15dB or VSWR have below 1.5
The part of antenna connection fasten to port not to be loosed and not to be injected the dusty and
insects
The antenna connected to RU is only serviced in in-building
6.3 Grounding
A ground cable is included in the box. The grounding terminals are located at the rear of the ADXV HE and RU.
The grounding cable should be properly connected before powering on the equipment.
Figure 6-3 HE Ground Cable Connection, Protective Earthing Conductor (HE chassis rear side)
Figure 6-4 RU Ground Cable Connection, Protective Earthing Conductor (RU chassis rear side)
Round terminals located on the side of a 1.25mm²(16AWG)or more wires Using permanently connected to
earth(Protective earthing conductor).