User's Manual

Advanced RF Technologies, Inc.
30
The ADXV-H-ODU-4 has the following LEDs on the front panel as shown in Figure 3-14.
Figure 3-14 ADXV-H-ODU-4 LED
Table 3-5 ODU LED Specifications
ADXV DAS-Module
Specifications
PWR
Solid Green
Module power is ON
OFF
Module power is OFF
LD
OFF
ODU is not installed
Solid Yellow
LD Fail alarm exists in the ODU
Solid Green
No LD Fail alarm is present in the ODU
PD1 to PD4
Solid Yellow
PD Fail alarm exists
Solid Green
No PD Fail alarm is present
3.1.5.2 RF Ports
Figure 3-15 ODU RF Ports
3.1.5.2.1 DL IN/UL OUT
The combined downlink signal received from ADXV-H-CHC is transferred to the DL IN at the back of ODU.
The UL OUT port connects any of the ports on back of the ADXV-H-CHC labeled UL 1 ~8.
3.1.5.2.2 VHF DL/VHF UL
VHF DL/UHF UL ports are used to support Public Safety in the VHF & UHF frequency bands. VHF/UHF signals
for Public Safety bypass the ADXV-H-CHC and connect directly to the VHF DL/UHF UL ports of the ADXV-H-ODU.
3.1.5.3 Optic Ports
LINK 4 LINK 3 LINK 2 LINK 1
Figure 3-16 ODU Optic Ports
The ADXV-H-ODU4 has (4) optic ports and can support up to (4) Main RU’s. Likewise, the ADXV-H-ODU1 has (1)
optic ports and can support up to (1) Main RU.
3.2 Remote Unit (RU)
- A remote unit (single RU chassis base) is composed of an ORU (Optical Remote Unit), a PSU
(Power Supply Unit) and plural bands RM (Remote Module).
Specifications
- Size: 19.0 x 15.0 x 7 inches (482 x 380 x 178 mm)
- Weight: 62.17lbs (28.2 Kg)@4 RM(337F/33S8C/37P/37A), ORU and PSU
- Power Input: 110VAC(optional) or -48VDC
PWRLDPD4PD3PD2PD1
UL OUT
DL IN VHF ULVHF DL