6.2.2 ADXV-HPR Installation Procedure
The ADXV-HPR chassis mounts in a standard 19” (483mm) equipment rack. Allow clearance of 3” (76mm) at
the front and rear, and 2” (51mm) on both sides for air circulation. No top or bottom clearance is required.
Consideration:
- Eight mounting holes (two holes at each corner of ADXV-HPR rack) are to attach it to the 19” rack.
The ADXV-HPR must be securely attached to a rack that can support the weight of the ADXV.
Procedure
- The following steps should be followed while mounting the ADXV-HPR
Verify that the ADXV-HPR and Mounting holes are in good condition
Set the ADXV-HPR against the 19”rack and secure the unit with screws
Verify that ADXV-HPR is securely attached
Connect the GND cable
Connect the RF coaxial cable
Connect the Power
Connect the Optic cable