User's Manual

Advanced RF
Technologies, Inc.
41
6.2.2 ADXV-HPR Installation Procedure
The ADXV-HPR chassis mounts in a standard 19(483mm) equipment rack. Allow clearance of 3(76mm) at
the front and rear, and 2” (51mm) on both sides for air circulation. No top or bottom clearance is required.
Consideration:
- Eight mounting holes (two holes at each corner of ADXV-HPR rack) are to attach it to the 19” rack.
The ADXV-HPR must be securely attached to a rack that can support the weight of the ADXV.
Procedure
- The following steps should be followed while mounting the ADXV-HPR
Verify that the ADXV-HPR and Mounting holes are in good condition
Set the ADXV-HPR against the 19”rack and secure the unit with screws
Verify that ADXV-HPR is securely attached
Connect the GND cable
Connect the RF coaxial cable
Connect the Power
Connect the Optic cable