User's Manual

Advanced RF Technologies, Inc.
28
3.2.1.2 RF port
DL/FB/UL ports of RM connect to ORU’s DL port, FB port and UL port in the same ID number equal to for
RM ID number.
CPL (-30dB): DL output 30dB coupling
SERVER: DL output, UL input, Server Duplexer port
3.2.1.3 LED
LED color
Status
Green
Normal
Yellow
Soft fail
Red
Hard fail
3.2.2 Optic Remote Unit (ORU, ADXD-R-ORU)
Figure 3-16 ADXD-R-ORU Front and Rear View
Spec
- Size: 3.2 x 17.0 x 6.86 (in)
- Weight: 7.0 lbs
3.2.2.1 Front port
- DL1-DL6: DL port connect to DL of RM (Remote Module) (see 3.2.1.1)
- FB1-FB6: FB port connect to FB of RM (Remote Module) (see 3.2.1.1)
- UL1-UL6: UL port connect to UL of RM (Remote Module) (see 3.2.1.1)
- M-SFP: Optic port connects to HE- ODU
- D-SFP: Optic port connects to another RU for daisy chain
ADXD-R-O
RU
SERVICE
MAIN
DAISY
GUIB / HM-SFPD-SFPOPTIC S/W
ULFBDL
8
7
6
5
4
3
2
1
8
7
6
5
4
3
2
1
D-SFP
M-SFP
from-M
to-D