6.2.3 Control/Install Tab
6.2.3.1 Control/Install NMS
6.2.3.1.1 SNMP
Figure 6-3 SNMP
In the SNMP section, you can configure SNMP Trap operation, Trap Interval, and Trap Manager. The
Manager IP field is where the user enters the IP address of the NOC system used to monitor SNMP traps. You
can also configure other settings for the Trap.
6.2.3.1.2 Location
This section allows the user to input the latitude and the longitude of the repeater.
Figure 6-4 Location Setting (Install NMS)
Select N or S from the dropdown menu for Latitude
Select E or W from the dropdown menu for Longitude
Input the first 3 numbers of the latitude/longitude in the text area after the “+” and before the “.”
Input the last 6 numbers of the latitude/longitude in the text area after the “.”
6.2.3.1.3 Remote Ethernet Setting
In this section, you can specify alternate IP, subnet mask, and gateway settings. This setting is enabled after
the host / remote switch is set to the remote location and the static setting (Use the following IP Address) is
set. the LAN1 setting is also used to configure the daisy chain system.