DL Output ALC Offset
To set the Max output ALC Offset
-10 ~ 0dBm
0.5dBm
Administrator
UL Output ALC Offset
To set the Max output ALC Offset
-20 ~ 0dBm
0.5dBm
Administrator
8.2.3.3.5 Alarm Setting
Figure 8-48 Alarm Threshold Setting (Control – RFU)
Table 8-16 Description for Alarm Threshold Setting (Control – RFU)
Name
Description
Range
Default
threshold
Downlink Signal Low
Allows the user to specify the minimum incoming DL input signal level
before triggering a “Downlink Signal Low” soft-fail alarm.
-10 ~ 20dBm
-5dBm
Downlink Signal Not
Detected
Allows the user to specify the minimum incoming DL input signal level
before triggering a “Downlink Signal Not Detected” soft-fail alarm.
-10 ~ 20dBm
-10dBm
Uplink Over Power
Allows the user to specify the how strong the output signal of uplink can
be before triggering an “Uplink Over Power” Hard Fail alarm.
-20 ~ 0dBm
0dBm