User's Manual Part 3

Advanced RF Technologies, Inc.
110
9. SYSTEM SPECIFICATION
9.1 Specification for PS78, SMR
Parameters
PS78
SMR
Frequency
Downlink
P7
758-775MHz
S8
851-869MHz
S9
929-930MHz
935-940MHz
Uplink
P7
788-805MHz
S8
806-824MHz
S9
896-901MHz
Input Power Range
0~+25dBm
Gain
Downlink
5~30dB, 0.5dB step, ATT range: 0~25dB
Uplink
-5~30dB, 0.5dB step, ATT range: 0~35dB
Maximum
Output
Power
1
Downlink at
RU
30dBm±2dB
Uplink at HE
-15dBm±2dB
Noise Figure
< 10dB@maximum gain
VSWR
< 1:1.5
Optical Loss
0~5dBo
System Delay
< 2us
Spurious
Meet FCC rules, 3GPP TS 36.104, 3GPP2 C.S0010-C
Nominal
Band/BW
for Industry
Canada
Downlink
P7
749-781 MHz
S8
840-880MHz
S9
925-949MHz
Uplink
P7
782-831 MHz
S8
811-834MHz
S9
887-911MHz
Dimension
(WXDXH)
Head-End Shelf
19.0 x 14.6 x 12.2 inches (482 x 370 x 311 mm)
Remote-Unit
Shelf
19.0 x 12.9 x 10.5 inches (482 x 328.2 x 266.5 mm)
Master RU
11.8 x 9.8 x 4.5 inches (300 x 249.6 x 114.5 mm)
Slave RU
11.8 x 9.8 x 3.7 inches (300 x 249.6 x 94.5 mm)
Weight
Head-End Shelf
83.7 lbs (38.0 Kg) @4 RFU, CHC-H, PSU and NMS
Remote-Unit
Shelf
61.0 lbs (27.7 kg) @ 1 master RU, 3 Slave RU
Master RU
13.2 lbs (6.0 kg)
Slave RU
11.7 lbs (5.3 kg)
Operating Temperature
14-122F(-10-50°C)
Operating Humidity
5~90%RH
Power Input
110/220V, 50-60Hz, 24V or -48V DC(optional)
Power
Head-End
52W@4 RFU, 1 ODU Rack with 2 ODUs and NMS
1
The Manufacturer's rated output power of this equipment is for single carrier operation. For situations when
multiple carrier signals are present, the rating would have to be reduced by 3.5 dB, especially where the output
signal is re-radiated and can cause interference to adjacent band users. This power reduction is to be by means of
input power or gain reduction and not by an attenuator at the output of the device
메모 [H5]: 주파수 범위 수정 15/05/19
메모 [Y6]: 실제로 측정하셔
기입요청합니다.
15/02/03