User's Manual Part 1

Advanced RF Technologies, Inc.
30
UL5UL6UL7UL8
DL5DL6DL7DL8
UL1UL2UL3UL4
DL1DL2DL3DL4
Figure 3-12 ADX-H-CHC Front & Rear View
Functions & Features
- Combines DL signals received from each RFU and feeds the combined signals to the ADX-H-OPT
- Combines UL signals received from each RU and feeds the combined signal to the ADX-H-RFU
- Supports up to 8 RFUs and (4) ADX-H-OPT-8 or (4)ADX-H-OPT-4
- Channel Combiner is not connected to VU RFU because VU RFU internally includes 8way combiner for
connection to 8 ODUs VHF ports
Specifications
- Size: 16.9 x 12.9 x 1.7 inches
- Weight: 11.0 lbs
3.1.3.1 RF ports
3.1.3.1.1 RF ports at the front panel (DL 1 to DL 8, UL 1 to UL 8)
DL 1(to DL 8) & UL 1(to UL 8) RF ports are connected to DL OUT/UL IN Ports at the front panel of RFU.
Receive the downlink signal from each RFU
Split the uplink signal received from ODU to each RFU
3.1.3.1.2 RF ports at the back panel (DL 1 to DL 8, UL 1 to UL 8)
DL 1(to DL 8) & UL 1(to UL 8) RF ports are connected to DL IN/UL OUT Ports at the back panel of OPT.
Transfer the combined downlink signals to OPT
Receive the uplink signal from ODU
3.1.3.2 RF ports
3.1.3.2.1 RF ports at the front panel( DL 1 to DL 8, UL 1 to UL 8)
DL 1(to DL 8) & UL 1(to UL 8) RF ports are connected to DL OUT/UL IN Ports at the front panel of RFU.
Receive the downlink signal from each RFU
Split the uplink signal received from ODU to each RFU
3.1.3.2.2 RF ports at the back panel( DL 1 to DL 8, UL 1 to UL 8)
DL 1(to DL 8) & UL 1(to UL 8) RF ports are connected to DL IN/UL OUT Ports at the back panel of OPT.
Transfer the combined downlink signals to ODU
Receive the uplink signal from ODU
3.1.4 Optic Distribution Unit (ADX-H-ODU + ADX-RACK-ODU)