User's Manual
Advanced RF Technologies, Inc.
36
3.1.5.1 LEDs
ADX-H-PSU has the following LEDs on the front panel as shown in Figure 3-18.
POWER
CHG STS
LOW BAT
T
AC FAIL
DC FAIL
Figure 3-18 HE PSU LED
Table 3-4 HE PSU LED Specifications
ADX DAS-Module Specifications
Power
Solid Green
ADX-H-PSU power is ON
OFF
ADX-H-PSU power is OFF
CHG STS
Solid Yellow
No AC power is available and ADRF-BBU is being used
Blinking Green
PSU is charging the ADRF-BBU
Solid Green
ADRF-BBU is completely charged
OFF
Battery is not connected
LOW BATT
Solid Yellow
Low Battery alarm exist in the PSU
Solid Green
No Low Battery alarm is present in the PSU
AC FAIL
Solid Yellow
AC Fail alarm exists in the PSU
Solid Green
No AC Fail alarm is present in the PSU
DC FAIL
Solid Yellow
DC Fail alarm exists in the RFU
Solid Green
No DC Fail alarms is present in the PSU
3.1.5.2 AC Input On/Off Switch, AC Input Port and AC Input Selection Switch
ON/OFFAC IN
A
C SELEC
T
Figure 3-19 HE PSU AC Input On/Off Switch, AC Input Port and AC Input Selection Switch
The AC Power on/off switch is located at the back panel of HE PSU. The ADX-H-PSU can operate at 110V AC
and 220V AC. The user should verify that the AC input voltage switch is set to the correct voltage before powering
on the ADX-H-PSU.
3.1.5.3 Battery Backup Port, Battery Install Port and Battery Backup Switch
BATTERY
INSTALL
BATTERY
24V 1A
BATTERY
OFF
S/WOFF ON
Figure 3-20 Battery Backup Port, Battery Install Port and Battery Backup Switch
The Battery Switch can be used to provide power to the optional External Backup Battery (ADRF-BBU) (Figure
3-20).