Table 8-20 Description for Manual Atten Control (Control - RU)
Name Description Range
Default
threshold
Available Accounts
Downlink Atten
Allows the user to specify how much attenuation to use.
0 ~ 30dB
30dB
Administrator, User
Uplink Atten
Allows the user to specify how much attenuation to use.
0 ~ 25dB
25dB
Administrator, User
DL Output ALC
Level
The remote module will prevent the downlink output
power from exceeding the specified value.
5 ~ 30dB
30dBm
Administrator, User
UL Output ALC
Level
The system will prevent the output power to exceed the
specified value.
0 ~ 10dBm
5 or
6dBm
Administrator
DL Output ALC
Offset
When the incoming signal level increases, the system will
not adjust the gain levels until it reaches the ALC Offset
Level.
0 ~ 10dB
5dB
Administrator, User
UL Output ALC
Offset
When the incoming signal level increases, the system will
not adjust the gain levels until it reaches the ALC Offset
Level.
0 ~ 10dB
3dB Administrator
8.2.3.6.5 Alarm Setting
Figure 8-59 Alarm Setting (Control - RU)
x DL Over Power Limit: The overpower alarm threshold can be adjusted from 5~30dBm. +2dB from the DL
overpower limit will trigger a soft fail and >2dB will trigger a hard fail alarm
x VSWR Alarm ON : Enable or disables the VSWR Alarm.