User's Manual

Advanced RF Technologies, Inc.
40
BATTERY S/W
BATTERY 24V
OFF
OFF ON
Figure 3-35 Battery Backup Port & Battery Backup Switch
When the Battery S/W is set to the ON position, the power supply charges the optional ADRF-BBU (External
Backup Battery) (Figure 3-35).
The RU PSU can be connected to an ADRF-BBU (ADRF Battery Backup Unit) to provide power during a power
failure. If an ADRF-BBU is utilized, connect the ADRF-BBU to the RU PSU via the external battery backup port as
shown in Figure 3-35.
(WARNING: The circuit switch on the ADRF-BBU must be set to OFF before connecting the ADRF-BBU to the
HE PSU to prevent damage to the HE PSU or the ADRF-BBU and personal injury.)
Note: Please contact ADRF Technical Support for assistance if you are unfamiliar with the installation
procedure of our battery box.
The procedure for connecting RU PSU to BBU
 BATT S/W OFF
 Connect BBU to RU PSU Battery port using RU battery cable
 BATT S/W ON
3.2.3.2.4 DC Output Port
DC OUT
+27V
Figure 3-36 DC Output Port (RU PSU)
x (8) DC output ports are available to connect up to 8 remote modules (Master or Salve RU’s)
3.2.3.2.5 PSU Alarm Port
PSU ALARM
Figure 3-37 PSU Alarm Port (RU PSU)
x Connects to the Master RU to monitor the status of the ADX-R-PSU-30
x The ADX-H-NMS & Master RU monitor the status of the ADX-R-PSU-30 via this port