User's Manual
Advanced RF Technologies, Inc.
83
Table 8-11 Description for HRU Commissioning status
Status Display Description
Installed Status
Installed
Text is black
Not-Installed
Text is gray
Commissioning Status
Success
Green
Fail or not yet
Gray
8.2.2.5.3 Alarm
Table 8-12 Alarm Status (Status - HRU Hub)
Alarm
Severity
Description
System
Link Fail
Soft Fail
Present when a module cannot communicate with the
NMS
System Halt
Hard Fail
System will go into a “System Halt” state when a hard
fail alarm does not clear after 10 checks.
System Halt
can only be cleared with a power cycle, reboot, or
factory settings.
Power Alarm
AC Fail
Soft Fail
AC power is not within parameters.
DC Fail
Soft Fail
DC power is not within parameters.
Over Current
Hard Fail
Total current of HRU is
higher than the threshold level
for over current alarm
Battery Low
Soft Fail
Voltage of battery connected to HRU PSU is lower than
the defined threshold
8.2.2.6 Status – Remote module
Figure 8-28 Status – Remote Module