User's Manual Part 2
AdvancedRFTechnologies,Inc. 54
6.2.2 RUInstallationProcedure
CAUTION: ADXDASRUshouldbeinstalledinsidebuildingonly.
6.2.2.1 InstallingaADXDASRUinarack
IftheADXRUchassisisbeingwallmountedthenallowclearanceof3”(76mm)frontandrear,and2”(51mm)
onbothsidesforaircirculation.Notoporbottomclearanceisrequired.
When ADX DAS RU mounts in a standard
19” equipment rack, rack or wall type fan is needed for heat
dissipation.Theracktypefan(ADX‐R‐FAN)musthaveatleast1.75"ofclearance.
Consideration:
‐ Eightmountingholesarelocatedon4cornersofADXRUtoattachittothe19”rack.TheADX
RUmustbe
securelyattachedtosupporttheweightoftheADX‐RUunits.
Mountprocedure
‐ ThefollowingstepsshouldbefollowedwhilemountingtheADX‐RUunits
DetachthewallmountbracketlocatedatthebaseoftheADX‐RUchassis
VerifythattheRU
andMountingholeareingoodcondition
ScrewtheADXDASRUtothe19”rack
MakesuretheADXRUissecurelyattached
ConnecttheGNDcable
ConnecttheRFcable
ConnectthePower
ConnecttheOpticcable