User's Manual Part 2

AdvancedRFTechnologies,Inc.  76
Table89 SummaryDescription
Parameters Description
Connected DisplaysthenumberofRemoteModule’sconnectedtotheADXHOPT.
SoftFail Displaysthetotalnumberofsoftfailpresent.
HardFail Displaysthenumberofhardfailpresentoneachmodule.
LinkFail Displaysthenumberoflinkfailpresentoneachmodule.
NotCommissioned Displaysthenumberofnoncommissionedorcommissionfailedmodule.
Commissioned Displaythenumberofsuccessfullycommissionedmodule
8.2.2.4.2 RFStatus
DisplaystheDLinputpowerandtheULoutputpowerforeachODU.
AnODURackiscomposedof2ODUs.
Figure821 RFStatus(Status OPT)
8.2.2.4.3 OpticStatus
DisplayLDPowerandPDPowerforeachopticpath.LDPoweristhepower
thatisbeingsenttotheRUand
PDPoweristhepowerthatisbeingreceivedfromtheRU.
Figure822 OpticStatus(StatusODU)
8.2.2.4.4 OpticAtten(AdminOnly)
TheADXHODUhas3typesofattenuators.
DownlinkCommonAttenuator‐Displaysthecommonattenuation
levelontheDLpath.
UplinkCommonAttenuator‐DisplaysthecommonattenuationlevelontheULpath.
UplinkOpticAttenuator‐Displaystheamountofattenuationusedateachopticallink.