User's Manual Part 2
AdvancedRFTechnologies,Inc. 70
8.2.2.1.4 HECommissioningStatus
DisplaycommissioningstatusofeachHEcomponent.
Figure8‐9 HECommissioningstatus
Table8‐6 DescriptionforHECommissioningstatus
Status Display Description
InstalledStatus
PhysicallyInstalled Textisblack
PhysicallyNot‐Installed Textisgray
CommissioningStatus
Success Green
Failedornotcommissioned Gray
8.2.2.1.5 Alarm
Displaysalarmstatus oftheNMS.Ifanalarmispresentinthe system,thecolorof thesystemalarmtabwill
changeaccordingtothetypeoffailure.
Table8‐7 DescriptionforNMSalarm
Alarm Severity Description
System
OverTemperature
HardFail/
SoftFail
TemperatureofNMSishigherthanthethreshold
levelforovertemperaturealarm
UnderTemperature SoftFail
TemperatureoftheNMSislowerthanthethreshold
levelforundertemperaturealarm
SystemHalt HardFail HEsystemhalt
PowerAlarm
ACFail SoftFail ACpowerisoperatingoutsideofitsnormalrange
DCFail SoftFail DCpowerisoperatingoutsideofitsnormalrange
OverCurrent HardFail
TotalcurrentofHEishigherthanthethresholdlevel
forovercurrentalarm
BatteryLow SoftFail
VoltageofbatteryconnectedtoHEPSUislowerthan
thedefinedthreshold