User's Manual Part 1
AdvancedRFTechnologies,Inc. 39
3.2.2.3 PowerOn/OffSwitch&DCINPort
PowerOn/Offswitch
‐ SlaveRUPowerOn/Offswitch
DCINPort
‐ ConnectedtoDCoutputportofAC/DCadaptor(ADX‐R‐ADP‐30)orRUPSU(ADX‐R‐PSU‐30)
3.2.2.4 RS‐485Port
SlaveRUshouldbe
connectedtomasterRUinadiasychainstructureusingRS‐485linetomonitorandcontrol
slaveRUs.
TheRS‐485cableconnectedtomaster RU should beconnectedto RS‐485 INportofslaveRU. When a slave
RUisconnectedtoanotherslaveRU,then
theRS‐485cableshouldbeconnectedfromtheRS‐485OUTportto
theRS‐485INofthe2
nd
SlaveRU.(Figure3‐23)
IfRS‐485portconnectionsbetweenRemoteModulesarenotcorrect,masterRUwillnotbeabletorecognize
allsubordinateslaveRUs.(Figure3‐24)
WARNING! The RS‐485 ports should NEVER be connected to the Enthernet port of laptop or Ethernet
NetworkEquipment.Doing so maycause serious damage to the RemoteModulesornetworkequipments.
(Figure3‐25)
3.2.3 RUPowerSupplyOptions
3.2.3.1 ADX‐R‐ADP(RUPowerAdapter)
TheADX‐R‐ADP‐30iscapableofpowering1remotemodule(MasterorSlaveRU).
3.2.3.2 ADX‐R‐PSU(RUPowerSupplyUnit)
Figure3‐32 RUPSUFront&RearView
Functions&Features
‐ Providespowerto8remotemodules(MasterorSlaveRU)
‐ SupportsADRF‐BBUBatteryBackup
Spec