User's Manual Part 1

AdvancedRFTechnologies,Inc.  38
Figure329 SlaveRULED
Table35 SlaveRULEDSpecifications
ADXDASModule Specifications
Power SolidGreen ModulepowerisON
OFF Modulepower is OFF
SoftFail SolidYellow SoftFailalarmexists intheSlaveRU
SolidGreen NoSoftFailalarms arepresent intheSlaveRU
HardFail SolidRed HardFailalarmexists intheSlaveRU
SolidGreen NoHardFailalarmsarepresentintheSlaveRU
3.2.2.2 RFPorts
Figure330 RFPorts(SlaveRU)
3.2.2.2.1 DLIN&ULOUT
ConnectstooneoftheavaialbleDL2to4/UL2to4portsoftheMasterRU
DLINportreceivesthedividedDLoutputfromtheMasterRU
UL
OUTporttransferstheULoutputofslaveRUtotheMasterRU
3.2.2.2.2 SERVER&CPL
ServerPort
ConnectsdirectlytoaserverantennaortheADXRCHC(remotechannelcombiner)
CPLPort
30dBcouplingportoffoftheserverport
3.2.2.2.3 EFDL
IN/EFDLOUT&EFULIN/EF‐ULOUT
ConnecttoanexternalDL/ULfilter
DLexternalfiltercanbeusedtoreduceoutbandemissions
ULexternalfiltercanbeusedtoreduceuplinkoutbandsignals
BTandVURUdonothaveexternalfilter
portsbecausetherearenoissuesforexternalfiltering
Figure331 Portsattherearpanel(SlaveRU)
DL IN
SERVER
CPL(-30dB)
UL OUT
EF-DL OUT EF-DL IN EF-UL IN EF-UL OUT
P
O
WE
R
SOFT FAI
L
HA
R
D FAIL