User's Manual Part 1
AdvancedRFTechnologies,Inc. 38
Figure3‐29 SlaveRULED
Table3‐5 SlaveRULEDSpecifications
ADXDAS‐Module Specifications
Power SolidGreen ModulepowerisON
OFF Modulepower is OFF
SoftFail SolidYellow SoftFailalarmexists intheSlaveRU
SolidGreen NoSoftFailalarms arepresent intheSlaveRU
HardFail SolidRed HardFailalarmexists intheSlaveRU
SolidGreen NoHardFailalarmsarepresentintheSlaveRU
3.2.2.2 RFPorts
Figure3‐30 RFPorts(SlaveRU)
3.2.2.2.1 DLIN&ULOUT
ConnectstooneoftheavaialbleDL2to4/UL2to4portsoftheMasterRU
DLINportreceivesthedividedDLoutputfromtheMasterRU
UL
OUTporttransferstheULoutputofslaveRUtotheMasterRU
3.2.2.2.2 SERVER&CPL
ServerPort
‐ ConnectsdirectlytoaserverantennaortheADX‐R‐CHC(remotechannelcombiner)
CPLPort
‐ 30dBcouplingportoffoftheserverport
3.2.2.2.3 EF‐DL
IN/EF‐DLOUT&EF‐ULIN/EF‐ULOUT
ConnecttoanexternalDL/ULfilter
DLexternalfiltercanbeusedtoreduceout‐bandemissions
ULexternalfiltercanbeusedtoreduceuplinkout‐bandsignals
BTandVURUdonothaveexternalfilter
portsbecausetherearenoissuesforexternalfiltering
Figure3‐31 Portsattherearpanel(SlaveRU)
DL IN
SERVER
CPL(-30dB)
UL OUT
EF-DL OUT EF-DL IN EF-UL IN EF-UL OUT
P
O
WE
R
SOFT FAI
L
HA
R
D FAIL