User's Manual Part 1
AdvancedRFTechnologies,Inc. 37
TheIDofmasterRUcanbesetmanually usingADDRswitch.Thisswitch should onlybeuseifinstructedby
ADRFTechnicalSupport.
3.2.2 ADX‐R‐xxxS/ADX‐R‐BTxxS/ADX‐R‐VU25S(SlaveRU)
Figure3‐26 SlaveRUFront&RearView(excludingBTandVU)
Figure3‐27 SlaveRUFront&RearView(BT)
Figure3‐28 SlaveRUFront&RearView(excludingVU)
Functions&Features
‐ TransmitsDLsignalandreceivesULsignalthroughserverantennaport
‐ Individuallywall‐mountableor19”rack‐mountable(requiresADX‐R‐CHA)
‐ SupportsexternalfiltersviaDLandULpass‐throughports
Specification
‐ Size:11.8x9.8x3.7inches(300x249.6x94.5mm)
‐ Weight:11.7lbs(5.3kg)
3.2.2.1 LEDs
ADX‐R‐x30ShasthefollowingLEDsonthefrontoftheSlaveRUasshownbelowinFigure3‐29.