User's Manual Part 1

AdvancedRFTechnologies,Inc.  34
SoftFail SolidYellow SoftFailalarmexists intheMasterRU
SolidGreen NoSoftFailalarms arepresent intheMasterRU
HardFail SolidRed HardFailalarmexists intheMasterRU
SolidGreen NoHardFailalarmsarepresentintheMasterRU
OpticFail SolidYellow OpticFailalarmexists intheMasterRU
SolidGreen NoOpticFailalarmispresentintheMasterRU
COMM SolidYellow COMMFailalarmexists intheMasterRU
SolidGreen NoCOMM FailalarmispresentintheMasterRU
3.2.1.2 RFPorts
Figure321 RFPorts(MasterRU)
3.2.1.2.1 MDL/MUL,DL1toDL4&UL1toUL4
MDL/MULports
MasterRUunitswillcomewiththeMDLandMULportspreconnectedtotheDL1andUL1ports.
DL2toDL4&UL2toUL4ports
SlaveRU’sconnecttotheDL2~DL4andUL2~UL4ports.
3.2.1.2.2 EDL/EUL
TheEDL/EULportsconnecttotheADXR4WS(4waysplitter)
TheADXR4WSwillprovideanadditional(4)DLandUL
portstoconnectupto(4)additioanlSlaveRU’s
ADXR4WSdividestheoutputofEDL porttoextendedslaveRUsandcombines/transfersULsignalreceived
fromextendedslaveRUstoEULport.
3.2.1.2.3 VHFDL/VHFUL
ConnectstotheADXRV25S(VHFSlave
RU)forpublicsafetyserviceintheVHF/UHFbands
3.2.1.2.4 SERVER&CPL
ServerPort
ConnectsdirectlytoaserverantennaortheADXRCHC(remotechannelcombiner)
CPLPort
30dBcouplingportoffoftheserverport
3.2.1.2.5 EFDLIN/EFDLOUT&EF
ULIN/EF‐ULOUT
ConnectstoanexternalDL/ULfilter
DLexternalfiltercanbeusedtoreduceDLoutbandemissions
ULexternalfiltercanbeusedtoreduceoutbandfrequenies
BTRUdoesnothaveexternalfilterportsbecausetherearenoissues
forexternalfiltering